Member LinuxUnix80 reports:
DO NOT update your inverters (definitely applies to HMS-1600, HMS-1800 and HMS-2000) to version 2.00.04.
At least not if you are using DPL. As long as the active power is below 100%, everything is fine. However, if a request is made to go to 100% power, this is displayed in OpenDTU, but the output power remains at the last value!
Only a new manual setting regulates the output power again.
I have now downgraded to version 1.1.12. Now everything works as usual again.
If you have set the output power to a fixed value, you won't have any problems.
Btw: Message 223 is no longer reported with version 2!
- Home
- FAQ
- First-Time Installation
- Device Profiles (Pin Config)
- Upgrade from OpenDTU
- Getting Help
- Hilfe erhalten
- Builds & Examples
- ESP32 Versions and Memory
- Victron MPPT solar charger
- VE.Direct
- Victron Smartshunt
- Victron Smart Battery Sense
- Warning on Victron MPPT 100/20
- Pylontech battery
- Pytes battery
- Huawei AC PSU
- SBS Unipower Battery
- Jikong JK BMS
- HOYMILES
- Einschaltstrombegrenzung für Balkonkraftwerke - Inrush current limiter
- Zendure SolarFlow with OpenDTU‐OnBattery
- Live View
- Farbe des Wechselrichterfensters
- Power Meter
- Dynamic Power Limiter
- Dynamic Power Limiter ‐ (Full) Solar‐Passthrough
- Dynamic Power Limiter Limitations
- DC Voltage ‐ Load correction factor
- Battery
- Battery-Tipps
- 24V Battery issues with Hoymiles
- Home Assistant
- Grafana Dashboard
- XXL Balkonkraftwerk 1500 Watt und mehr! Worauf Ihr achten solltet!
- Wie gefährlich kann ein Balkonkraftwerk werden (FI‐Schutzschalter)
- Hardware Purchase Tipp
- Fan speed controller ‐ add temperature sensing to any fan
- Cable length(s) between battery and inverter
- Kabellänge(n) zwischen Batterie und Wechselrichter
- Diodes ‐ Bypass vs. Blocking Diodes
- Impact of high start-currents to the inverter
- Making Cables for your HOYMILES‐CAUTION