-
Notifications
You must be signed in to change notification settings - Fork 1
OpenNeuro dataset - Test-retest reliability of multi-metabolite edited MRS at 3T using PRESS and sLASER
License
OpenNeuroDatasets/ds005371
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
# Test-retest reliability of multi-metabolite edited MRS at 3T using PRESS and sLASER Contact: Mark Mikkelsen, Ph.D. ([mam4041@med.cornell.edu](mailto:mam4041@med.cornell.edu)) ## Overview These data were collected as part of a study to assess the test-retest reliability of multi-metabolite edited MRS using [HERMES](https://doi.org/10.1016/j.neuroimage.2016.07.056) and [HERCULES](https://doi.org/10.1016/j.neuroimage.2018.10.002) editing and [PRESS](https://doi.org/10.1111/j.1749-6632.1987.tb32915.x) and [sLASER](https://doi.org/10.1002/mrm.21302) localization. Data types included are defaced *T*<sub>1</sub>-weighted 3D structural MRI images and single-voxel HERMES- and HERCULES-edited PRESS and sLASER MRS data. ## Methods ### Participants Sixteen healthy adults (10 females, 6 males, mean age = 38.4 ± 18.2 years). **Important note**: Data of two participants (sub-05 and sub-06) was not uploaded to this repository because they did not provide the relevant consent for data sharing. The data of the remaining 14 participants are available in this repository. ### Scanning Two 1-hr scan sessions for each participant separated by a time interval (median = 0 days; range = 0-29 days). ### MR protocol MR data were acquired on a 3T GE Discovery MR750 MRI scanner using a <sup>1</sup>H 32-channel RF phased-array head coil for receive and a body coil for transmit. #### MRI *T*<sub>1</sub>-weighted BRAVO structural MRI acquisition parameters: - FSPGR - TE/TR/TI = 5.2/12.2/725 ms - Flip angle = 7° - Voxel resolution = 0.9 × 0.9 × 1.5 mm<sup>3</sup> - FOV = 256 × 256 mm<sup>2</sup> - Matrix size = 256 × 256 - Slices = 124 - Parallel acquisition technique: GRAPPA - Parallel acquisition factor: 2 #### MRS General acquisition parameters: - Volume of interest = medial parietal lobe - Voxel resolution = 30 × 30 × 30 mm<sup>3</sup> - Spectral width = 5000 Hz - Number of points = 4096 - TE/TR = 82/2000 ms - Number of transients = 224 - Duration = 7 min 28 s - Double-echo GRE autoshimming - OVS = 3 orthogonal slabs HERMES: - Target metabolites: GABA and GSH - Two acquisitions: PRESS and sLASER - CHESS water suppression HERCULES: - Target metabolites: GABA, GSH, ascorbate, aspartate, lactate, NAA, and NAAG - Two acquisitions: PRESS and sLASER - VAPOR water suppression
About
OpenNeuro dataset - Test-retest reliability of multi-metabolite edited MRS at 3T using PRESS and sLASER
Resources
License
Stars
Watchers
Forks
Packages 0
No packages published