RSConnectGIOToSnap7

This is a RobotStudio Smart Component to connect GI/GO to SIEMENS PLC using Snap7 library.

What you have to do before compiling:

  • Update ABB.Robotics.* References to Good RobotStudio SDK Version path with Project - Add Reference - Browse.
  • On Project Properties:
    • Application: Choose good .NET Framework version.
    • Build Events: Post Build Events: Replace with the good LibraryCompiler.exe Path.
    • Debug: Start External Program: Replace with the good RobotStudio.exe Path This not work if project on network drive, let it clear.
  • In \RSConnectGIOToSnap7\RSConnectGIOToSnap7.en.xml:
    • Replace xsi:schemaLocation value with good one.
  • Same for \RSConnectGIOToSnap7\RSConnectGIOToSnap7.xml.

If your project path is on network drive:

To get RobotStudio load it:
  • In $(RobotStudioPath)\Bin\RobotStudio.exe.config file:
    • Add in section <configuration><runtime>
      • <loadFromRemoteSources enable="true"/>
To Debug it:
  • Start first RobotStudio to get RobotStudio.exe.config loaded.
  • Then attach its process in VisualStudio Debug - Attach to Process..

Usage

RSConnectGIOToSnap7

Properties

  • PLC_Addr:
    IP Address of PLC IPV4.
    For PLCSim, you have to run NetToPLCSim and enter PC IP.
  • PLC_Rack:
    S7_300 Rack=0
    S7_400 See HW Config
    S7_12xx/15xx Rack=0
  • PLC_Slot: S7_300 Slot=2
    S7_400 See HW Config
    S7_12xx/15xx Slot=1
  • GI_ByteNumber: Number of Byte for GI to connect to in Station Logic.
    Change it to get GI appearing.
  • GI_FirstByteAddress: First output byte to connect at GI.
    You can use: ABx QBx MBx DBx.DBBy
  • GO_ByteNumber: Number of Byte for GO to connect to in Station Logic.
    Change it to get GO appearing.
  • GO_FirstByteAddress: First input byte to connect at GO.
    You can use: EBx IBx MBx DBx.DBBy

Signals

  • Connect: Start to connect to PLC.
    If an error occurs, you can check if it is related to Sharp7 or Snap7 in their Forum
  • Read: Read GI on PLC one time. (Hidden if not connected)
    In simulation running, they are read continuously.
    GO are written each time they change.