Notifications
You must be signed in to change notification settings - Fork 7
Description
Branch
Summary and Purpose
There is currently no way to specify the wavelength of optical observations (as from remote sensing). The Frequencies feature type exists in WMDR with appropriate descriptors. However, units of frequency are not adequate for observations in the UV-VIS-NIR spectrum due to the significant digits required for accuracy (and units of nanometer or micrometer are standard).
Stakeholder(s)
lidar and other remote sensing
Proposal
A new Wavelengths feature type be created, modeled after Frequencies:
Wavelengths feature type:
- bandwidth
- bandwidthUnit (expected values are nanometer and micrometer)
- wavelength
- wavelengthUnit (expected values are nanometer and micrometer)
- wavelengthUse
- purposeOfWavelengthUse
- transmissionMode
This proposal requires that nanometer and micrometer (and/or micron) be added to the measurement unit code registry (they are currently missing).
Reason
These proposed changes will provide a way for users to specify the wavelength of their observations. Such information is critical for remote sensing data.