Hello,
Recently one of our drives failed which resulted the plugin check to give the message "Invalid StorCLI command!" as output.
I see this problem relates with #3
Drive summary:
[user@system nagios]$ sudo /opt/MegaRAID/storcli/storcli64 /c0/eall/sall show all
Controller = 0
Status = Failure
Description = Show Drive Information Failed.
Detailed Status :
===============
---------------------------------
Drive Status ErrCd ErrMsg
---------------------------------
/c0/e46/s0 Success 0 -
/c0/e46/s1 Success 0 -
/c0/e46/s2 Success 0 -
/c0/e46/s3 Success 0 -
/c0/e46/s4 Success 0 -
/c0/e46/s5 Success 0 -
/c0/e46/s6 Success 0 -
/c0/e46/s7 Success 0 -
/c0/e46/s8 Success 0 -
/c0/e46/s9 Success 0 -
/c0/e46/s10 Success 0 -
/c0/e46/s11 Success 0 -
/c0/e46/s12 Success 0 -
/c0/e46/s13 Success 0 -
/c0/e46/s14 Success 0 -
/c0/e46/s15 Success 0 -
/c0/e46/s16 Success 0 -
/c0/e46/s17 Success 0 -
/c0/e46/s18 Success 0 -
/c0/e46/s19 Success 0 -
/c0/e46/s20 Success 0 -
/c0/e46/s21 Success 0 -
/c0/e46/s22 Success 0 -
/c0/e46/s23 Success 0 -
/c0/e47/s0 Success 0 -
/c0/e47/s1 Success 0 -
/c0/e47/s2 Success 0 -
/c0/e47/s3 Success 0 -
/c0/e47/s4 Success 0 -
/c0/e47/s5 Success 0 -
/c0/e47/s6 Success 0 -
/c0/e47/s7 Success 0 -
/c0/e47/s8 Success 0 -
/c0/e47/s9 Success 0 -
/c0/e47/s10 Success 0 -
/c0/e47/s11 Success 0 -
/c0/e47/s12 Success 0 -
/c0/e47/s13 Success 0 -
/c0/e47/s14 Success 0 -
/c0/e47/s15 Success 0 -
/c0/e47/s16 Success 0 -
/c0/e47/s17 Success 0 -
/c0/e47/s18 Success 0 -
/c0/e47/s19 Success 0 -
/c0/e47/s20 Success 0 -
/c0/e47/s21 Success 0 -
/c0/e48/s0 Success 0 -
/c0/e48/s1 Success 0 -
/c0/e48/s2 Success 0 -
/c0/e48/s3 Success 0 -
/c0/e48/s4 Success 0 -
/c0/e48/s5 Success 0 -
/c0/e48/s6 Success 0 -
/c0/e48/s7 Success 0 -
/c0/e48/s8 Success 0 -
/c0/e48/s9 Success 0 -
/c0/e48/s10 Success 0 -
/c0/e48/s11 Success 0 -
/c0/e48/s12 Success 0 -
/c0/e48/s13 Success 0 -
/c0/e48/s14 Failure 45 -
/c0/e48/s15 Success 0 -
/c0/e48/s16 Success 0 -
/c0/e48/s17 Success 0 -
/c0/e48/s18 Success 0 -
/c0/e48/s19 Success 0 -
/c0/e48/s20 Success 0 -
/c0/e48/s21 Success 0 -
/c0/e48/s22 Success 0 -
/c0/e48/s23 Success 0 -
---------------------------------
...
Plugin service check results:
[user@system ~]$ sudo /opt/nagios/check_lsi_raid -p /opt/MegaRAID/storcli/storcli64 -C 0 -Im 100 -Io 100 -v
Invalid StorCLI command! (/opt/MegaRAID/storcli/storcli64 /c0/eall/sall show all)
[user@system ~]$ sudo /opt/MegaRAID/storcli/storcli64 /c0/eall/sall show all ; echo $?
...
45
[user@system ~]$ sudo /opt/MegaRAID/storcli/storcli64 adpallinfo a0 ; echo $?
...
Exit Code: 0x00
0
I first thought we were using an older version of the plugin but this does not seem the case, both Storcli & check_lsi_raid are up to date
check_lsi_raid: Nagios/Icinga plugin to check LSI Raid Controller status
Version: 2.5
StorCli SAS Customization Utility Ver 1.23.02 Mar 28, 2017
It might have something to do with return code 45 not being handled?