Hello,
rctmon is running as expected accept of some missing metrics regrading "household".
The only metrics I receive is:
# HELP rctmon_household_load Household load (sum over phases)
# TYPE rctmon_household_load gauge
rctmon_household_load{inverter="solar01"} 241.02685546875
# HELP rctmon_household_load_phase Household load by phase
# TYPE rctmon_household_load_phase gauge
rctmon_household_load_phase{inverter="solar01",phase="l1"} 42.8297119140625
rctmon_household_load_phase{inverter="solar01",phase="l2"} 139.6209716796875
rctmon_household_load_phase{inverter="solar01",phase="l3"} 49.4603271484375
But I am looking for:
Something like: energy.e_load_total or any of the other metrics that reports Wh instead of current W.
Here some infos about my rctmon:
# HELP rctmon_info Information about the application
# TYPE rctmon_info gauge
rctmon_info{version="0.0.1",version_major="0",version_minor="0",version_patch="1"} 1.0
# HELP rctmon_inventory Shows attached components
# TYPE rctmon_inventory gauge
rctmon_inventory{component="generator_a",inverter="solar01"} 1.0
rctmon_inventory{component="generator_b",inverter="solar01"} 1.0
rctmon_inventory{component="power_switch",inverter="solar01"} 0.0
# HELP rctmon_inverter_info Information about the inverter
# TYPE rctmon_inverter_info gauge
rctmon_inverter_info{control_software_version="2.3.5615",inverter="solar01",parameter_file="DE_ARN4105_1811_200326",serial_number="0065*********"} 1.0
# HELP rctmon_inverter_status Status of the inverter
# TYPE rctmon_inverter_status gauge
rctmon_inverter_status{inverter="solar01"} 13.0
# HELP rctmon_inverter_grid_separated Status of the island mode
# TYPE rctmon_inverter_grid_separated gauge
rctmon_inverter_grid_separated{inverter="solar01"} 2.0
# HELP rctmon_inverter_faults Fault registers
# TYPE rctmon_inverter_faults gauge
rctmon_inverter_faults{inverter="solar01",register="0"} 0.0
rctmon_inverter_faults{inverter="solar01",register="1"} 0.0
rctmon_inverter_faults{inverter="solar01",register="2"} 0.0
rctmon_inverter_faults{inverter="solar01",register="3"} 0.0
In the log I see that some unkown OIDs are received:
2022-09-12 07:29:54,734 - rctmon.device_manager - WARNING - _cb_grid: unhandled oid 0x63476DBE2022-09-12T07:29:54.734987191Z
2022-09-12 07:29:54,735 - rctmon.device_manager - WARNING - _cb_grid: unhandled oid 0x485AD7492022-09-12T07:29:54.735355414Z
2022-09-12 07:29:54,735 - rctmon.device_manager - WARNING - _cb_grid: unhandled oid 0xF25C339B2022-09-12T07:29:54.735624947Z 
2022-09-12 07:29:54,735 - rctmon.device_manager - WARNING - _cb_grid: unhandled oid 0x1C4A665F2022-09-12T07:29:54.736002418Z
In the RCT-App I am able to see the household Wh reading per day and month.