Skip to content

Limitless active_connection_id_limit #36

@QUICTester

Description

@QUICTester

Hi,

During testing commit 841c822, we discovered that the PQUIC server does not set a limit for its active_connection_id_limit transport parameter and able to process up to 1000 NEW_CONNECTION_ID frame.

According to RFC 9000, if the value of active_connection_id_limit is absent, a default limit of 2 is assumed. This means that if the number of active connection IDs exceeds the value advertised in its active_connection_id_limit transport parameter (which is 2 in this case), the server MUST close the connection with an error of type CONNECTION_ID_LIMIT_ERROR.