Skip to content

RTL Code Coverage Hole in cv32e40p_EX_stage module line 387 for FPU configuration #1017

@YoannPruvost

Description

@YoannPruvost

Component

Component:RTL

Issue Description

One of the possible combination in the if statement line 387of cv32e40p_EX_stage was not covered during all the simulation non-regressions.

After analysis we suspected that this scenario was in fact unreachable.
Siemens Questa Static formal tool was used to prove that this scenario was unreachable. For this scenario a dedicated assertion was written, named assert_unreachable_ex_387.

All information necessary to reproduce and analyze our work with formal can be found in the ReadMe in the cv32e40p/scripts/formal folder

As it was too late to implement a fix in the RTL due to long RISC-V ISA Formal Verification runs and requiring to update all waivers files as well, it has been decided to waive this scenario hole in v2.

387-396
387

Metadata

Metadata

Assignees

No one assigned

    Labels

    Component:RTLFor issues in the RTL (e.g. for files in the rtl directory)WAIVED:CV32E40PIssue does not impact a major release of CV32E40P and is waived

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet