Skip to content

Calibration out of date? #138

@snerd9334

Description

@snerd9334

float Vcal_EU= 256.8; // (230V x 13) / (9V x 1.2) = 276.9 - Calibration for EU AC-AC adapter 77DE-06-09

The model referenced here (77DE-06-09) is now no longer manufactured. It has been replaced with 77-DB-06-09.

Spec sheet for old model: https://www.farnell.com/datasheets/1596487.pdf
Spec sheet for new model: https://www.farnell.com/datasheets/1772940.pdf

There are differences between the specifications of the two transformers, so I wonder if the calibration figure on the line referenced at the top of this post needs updating?

Thank you

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions