Notifications
You must be signed in to change notification settings - Fork 204
Common.Logging.ETWLogger
Common.Logging.ETWLogger
provides an adapter for connecting Common.Logging to the Event-Tracing for Windows logging subsystem that is available on later editions of the Windows Operating System (both Servers and Clients). See MSDN for more information on Event-Tracing for Windows.
- Add the
Common.Logging.ETWLogger
NuGet package to your project. - To configure the logger in code, simply create an instance of the
Common.Logging.ETW.ETWLoggerAdapter
and call the.GetLogger(...)
method on the adapter as follows:
var adapter = new ETWLoggerAdapter();
var logger = adapter.GetLogger(typeof(MyClass));
logger.Warn("Message to Log here!");
- To Configure the logger via e.g., App.config, web.config files, add the relevant sections to your .config file:
<?xml version="1.0" encoding="utf-8" ?>
<configuration>
<configSections>
<sectionGroup name="common">
<section name="logging" type="Common.Logging.ConfigurationSectionHandler, Common.Logging" />
</sectionGroup>
</configSections>
<common>
<logging>
<factoryAdapter type="Common.Logging.ETW.ETWLoggerFactoryAdapter, Common.Logging.ETWLogger">
</factoryAdapter>
</logging>
</common>
</configuration>
Common.Logging.ETWLogger
offers several configuration options to control its behavior as follows:
Common.Logging.ETWLogger
makes use of the Microsoft.Diagnostics.Tracing.EventSource
NuGet package to expose an API for managed (.NET) code to communicate with the underlying native Event-Tracing for Windows (ETW) subsystem. Among other things, this library provides an EventSource
super-class from which developers must derive their own sub-class to communicate with ETW. Common.Logging.ETWLogger
provides a default sub-class derived from this EventSource
super-class and it is intended to meet the needs of most adopters of Common.Logging.ETWLogger
.
For more fine-grained control over the behavior of Common.Logging.ETWLogger
, developers can derive their own sub-class from the EventSource
super-class and configure Common.Logging.ETWLogger
to use your own custom type instead.
The Common.Logging.ETW.ETWLoggerAdapter
exposes a property that can be configured to contain an instance of your custom EventSource
-derived sub-class in code as follows:
var adapter = new ETWLoggerAdapter();
adapter.ETWEventSource = new MyCustomDerivedEventSource();
var logger = adapter.GetLogger(typeof(MyClass));
logger.Warn("Message to Log here!");
This can be configured in e.g., app.config, web.config files as follows:
<?xml version="1.0" encoding="utf-8" ?>
<configuration>
<configSections>
<sectionGroup name="common">
<section name="logging" type="Common.Logging.ConfigurationSectionHandler, Common.Logging" />
</sectionGroup>
</configSections>
<common>
<logging>
<factoryAdapter type="Common.Logging.ETW.ETWLoggerFactoryAdapter, Common.Logging.ETWLogger">
<arg key='commonLoggingEventSourceType' value='MyNamespace.MyCustomDerivedEventSource,MyAssemblyContainingTheCustomEventSource'/>
</factoryAdapter>
</logging>
</common>
</configuration>
In order for Common.Logging.ETWLogger
to properly interact with your custom EventSource
-derived sub-class, the following requirements must be satisfied:
- Your custom sub-class must derive from
Microsoft.Diagnostics.Tracing.EventSource
. Note: theMicrosoft.Diagnostics.Tracing.EventSource
package also places a number of other restrictions on types derived fromEventSource
and of course your own sub-class must satisfy all of these as well. There are two MSWORD documents containted in theMicrosoft.Diagnostics.Tracing.EventSource
package that cover these additional requirements in full detail. - Your custom sub-class must implement the
Common.Logging.ETW.ICommonLoggingEventSource
interface. This is aCommon.Logging
-specific interface thatCommon.Logging.ETWLogger
expects any customEventSource
-derived type to fully-implement. For more detail, see the full interface definition and refer to the default implementation of this interface provided withCommon.Logging.ETWLogger
as an example of this. - If you intend the
ETWLoggerAdapter
to be configued to use your custom sub-class via e.g., app.config, web.config, your custom sub-class must expose an empty/zero-arg constructor. At run-time, theETWLoggerAdapter
will use this ctor to instantiate an instance of your custom sub-class at run-time after reading the type declaration from the .config file. If this empty/zero-arg ctor isn't present,Common.Logging.ETWLogger
will throw an exception. Note: if you intend to only configure theETWLoggerAdapter
via code, then this empty/zero-arg ctor is not required.
The minimum logging level can be in code as follows:
var adapter = new ETWLoggerAdapter();
adapter.LogLevel = LogLevel.Error;
var logger = adapter.GetLogger(typeof(MyClass));
logger.Warn("Message to Log here!");
...and in e.g., app.config, web.config as follows:
<?xml version="1.0" encoding="utf-8" ?>
<configuration>
<configSections>
<sectionGroup name="common">
<section name="logging" type="Common.Logging.ConfigurationSectionHandler, Common.Logging" />
</sectionGroup>
</configSections>
<common>
<logging>
<factoryAdapter type="Common.Logging.ETW.ETWLoggerFactoryAdapter, Common.Logging.ETWLogger">
<arg key='level' value='error'/>
</factoryAdapter>
</logging>
</common>
</configuration>
Note that the LogLevel
setting is considered a minimum setting, with greater logging levels implicitly included. Consider the following example:
-
INFO
is a lower LogLevel thanERROR
- setting the
LogLevel
toERROR
will not logINFO
events - setting the
LogLevel
toINFO
will log all INFO events but also allERROR
events