iio: imu: bmi270: fix initial sampling frequency configuration
[ Upstream commit 6d03811 ]
In the bmi270_configure_imu() function, the accelerometer and gyroscope
configuration registers are incorrectly written with the mask
BMI270_PWR_CONF_ADV_PWR_SAVE_MSK, which is unrelated to these registers.
As a result, the accelerometer's sampling frequency is set to 200 Hz
instead of the intended 100 Hz.
Remove the mask to ensure the correct bits are set in the configuration
registers.
Fixes: 3ea5154 ("iio: imu: Add i2c driver for bmi270 imu")
Signed-off-by: Gustavo Silva <gustavograzs@gmail.com>
Reviewed-by: Alex Lanzano <lanzano.alex@gmail.com>
Link: https://patch.msgid.link/20250304-bmi270-odr-fix-v1-1-384dbcd699fb@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>