Notifications
You must be signed in to change notification settings - Fork 121
Open
Labels
Triage RequiredThis item still requires triage by a repository administrator.This item still requires triage by a repository administrator.Type: Bug/ObsolesceSomething isn't working/Part no longer available for saleSomething isn't working/Part no longer available for sale
Description
Discord Username
Ulukaii
Bug Summary
According th RS485 specification, the data lines A and B of a RS485 cable shall be twisted pair for increased EMI tolerance.
The OH spec sheet for cable manufacturing, OH-SPEC-002 - ABSIS CABLES_-_v1.pdf, does not mention this.
Expected Results
Add the following note to the ABSIS TYPE-A CABLE (RS485 BUS CABLE)
(...)
1.5 DATA LINES A AND B SHALL BE TWISTED ("TWISTED PAIR")
1.6 DO NOT TWIST ANY OTHER LINES
Add the following note to the ABSIS TYPE-E CABLE (RS485 BUS BULKHEAD CABLE):
(...)
1.5 DATA LINES A AND B SHALL BE TWISTED ("TWISTED PAIR")
1.6 DO NOT TWIST ANY OTHER LINES
Actual Results
Currently, there is no note.
Screenshots/Images/Files

Applicable Part Numbers
OH-SPEC-002
Release Version
v0.2.0
Category
Electrical (PCBs/Wiring/etc)
Applicable End Item(s)
Top Level Assembly (TLA)
Built to print?
- I built (or attempted to build) the part to the OpenHornet print without any deviations.
- I am not building this part to the OH print. (List deviations in detail in the Miscellaneous Info text area below.)
Miscellaneous Info
No response
Metadata
Metadata
Assignees
Labels
Triage RequiredThis item still requires triage by a repository administrator.This item still requires triage by a repository administrator.Type: Bug/ObsolesceSomething isn't working/Part no longer available for saleSomething isn't working/Part no longer available for sale