Describe the Bug
The duration of a timer start event within an event subprocess is lost, when the event is changed from non-interrupting to interrupting (or vice versa).
Steps to Reproduce
- Create an event sub process
- Make the start event a timer start event (non-interrupting or interrupting)
- Set the duration of the timer
- Use Change element on the start event and select interrupting or non-interrupting timer start event.
Sample model: timer-duration.bpmn.txt
Expected Behavior
The duration should be kept (it does work for dates and when using the toggle button).
Environment
- Library version: 18.6.1
- Found in Camunda Modeler 5.35.0