Boltzmann is not calculated when opt.Method = 'eig' , Exp.Temperature is invalid. #337

@cerium1925

Description

@cerium1925

For algorithms using general eigenvalue problems, when opt.Method = 'eig', the Boltzmann distribution is not calculated. In fact, there is no relevant calculation code in the original code of resfields_eig. Peak intensity calculation in the Matrix method is complete and includes all factors that may affect peak intensity.