hwmon: (tmp513) Fix interpretation of values of Temperature Result and Limit Registers
The values returned by the driver after processing the contents of the Temperature Result and the Temperature Limit Registers do not correspond to the TMP512/TMP513 specifications. A raw register value is converted to a signed integer value by a sign extension in accordance with the algorithm provided in the specification, but due to the off-by-one error in the sign bit index, the result is incorrect. According to the TMP512 and TMP513 datasheets, the Temperature Result (08h to 0Bh) and Limit (11h to 14h) Registers are 13-bit two's complement integer values, shifted left by 3 bits. The value is scaled by 0.0625 degrees Celsius per bit. E.g., if regval = 1 1110 0111 0000 000, the output should be -25 degrees, but the driver will return +487 degrees. Found by Linux Verification Center (linuxtesting.org) with SVACE. Fixes: 59dfa75 ("hwmon: Add driver for Texas Instruments TMP512/513 sensor chips.") Signed-off-by: Murad Masimov <m.masimov@maxima.ru> Link: https://lore.kernel.org/r/20241216173648.526-4-m.masimov@maxima.ru [groeck: fixed description line length] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
1 parent da1d0e6 commit dd471e2

File tree

1 file changed

+1
-1
lines changed

1 file changed

+1
-1
lines changed

drivers/hwmon/tmp513.c

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -234,7 +234,7 @@ static int tmp51x_get_value(struct tmp51x_data *data, u8 reg, u8 pos,
234234
case TMP51X_REMOTE_TEMP_LIMIT_2:
235235
case TMP513_REMOTE_TEMP_LIMIT_3:
236236
// 1lsb = 0.0625 degrees centigrade
237-
*val = sign_extend32(regval, 16) >> TMP51X_TEMP_SHIFT;
237+
*val = sign_extend32(regval, 15) >> TMP51X_TEMP_SHIFT;
238238
*val = DIV_ROUND_CLOSEST(*val * 625, 10);
239239
break;
240240
case TMP51X_N_FACTOR_AND_HYST_1: